Avidyne Entegra EXP5000 Instructions d'exploitation Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 58
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
EXP5000 Upper Half Display
600-00142-000 Rev 01 -7- Entegra EXP5000 PFD
2.2 EXP5000 Upper Half Display
Figure 2. EXP5000 Upper Half Display Symbols
Upper Half Display
The upper portion of the EXP5000 contains the following information:
1) M-BUS and E-BUS Data Block—Indicates Main and Essential
Bus voltages. The pop-up display allows you to check battery
voltages prior to engine start. It displays as soon as the engine is
started and remains until shortly after the Alternator comes online
and Bus voltages are within normal range.
Note: When the Bus voltages are below normal values, the display in red
(E-BUS) or yellow (M-BUS).
11
15
13
12
3
9
14
8
4
5
7
6
2
1
10
Vue de la page 12